Three phase output line reactors for VFD

Three phase filter reactor for converters at output side. It is installed between the output of the converter VDF and motor drive. Protection degree IP-00 with epoxy varnish finished.

 
 
 
Motor rating0,75 ÷ 630 kW (1 ÷ 855 CV)
Nominal current2 ÷ 1200 A
Nominal voltage380 V - 500 V
Inductive impedance± 3%
Max. converter output freq. 0 ÷ 70 Hz
Max. conmutation freq.10 kHz
Admissible overloadPermanent 1,07 x I.nom
 Transitory 1,5 x I.nom
Ambient temp.50 ºC @ I.nom
Insulation classF (155ºC)
Protection degreeIP-00
CoolingNatural air
Safety classClass I
Test voltage4 kV
MarkedCE
StandardIEC/UNE-EN 60076-6

 

 

Series IMT

694 KB

 
 
 

Electrical diagram

 

 

Dimensions

 

* TORYTRANS reserves the right to modify the information in any time
and without prior notice. Design, dimensions or weight of the product could be different. *

 
 
Versiones 1 to 1 of 1
 IMT002IMT004IMT006IMT008IMT010IMT015IMT020IMT025IMT030IMT040IMT050IMT060IMT080IMT100IMT125IMT150IMT200IMT250IMT300IMT400IMT500
Request offerRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequest
Current (A)2468101520253040506080100125150200250300400500
L (mH)10,9825,4913,6612,7452,1961,4641,0980,8790,7320,5490,4390,3660,2750,2200,1760,1460,1100,0880,0740,0550,044
Input Voltage(V)380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V380V ÷ 500V
IP000000000000000000000000000000000000000000
PhasesThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
UseOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFD
Frequency50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz50 Hz
Ambient temperature50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC
Thermic classF (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)
Electric shock protectionClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse I
Test voltage4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV
A120120120150150150190190190240240240240300300300300300360360420
B758484739898108113123131131151166163183173183193210210280
C122122122149164164205205205209209209209252252302302302363363470
D949494100100100140140140200200200200200200200200200320320280
E4757574762627277879090110125100120110120130130130165
ø6,56,56,577777777771111111111111111
Weight (Kg)1,21,71,82,33,73,95,46,27,69,610,114,718,421,12828,834,439,352,455,787,1
TypeIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII