Sinusoidal output filters for VFD IP00

Three phase sine wave voltage output filters especially designed for frequency converters. Remove pulses generated by the output voltage of the frequency converters PWM (pulse width modulation) at high frequencies and restore sinusoidal waveform at power converter´s output.

 
 
 
Motor rating0,37 ÷ 630 kW
(0,5 ÷ 855 CV)
Nominal current1 ÷ 1200 A
Output voltage of converter3 x 400 V ± 20 V
Output frequency of converter0 ÷ 70 Hz
Switching frequency5 ÷ 8 kHz hasta LC050
3 ÷ 5 kHz LC060 a LC200
2 ÷ 3 kHz a partir LC250
Voltage distortion≈ 8 % THD-U
Admissible overloadPermanent 1,07× I nom.
Transitory 1,5× I nom.
Ambiente temp.50 ºC
Insulation classH (180ºC)
Protection degreeIP-00 (up to ref. LC040)
IP-20 (from ref. LC050)
CoolingNatural air
MarkedCE
StandardIEC/UNE-EN 60076-6
IEC/UNE-EN 61588-2-20
 

Series LC

438 KB

 
 
 

Electrical diagram

 

 

Dimensions

 

* TORYTRANS reserves the right to modify the information in any time
and without prior notice. Design, dimensions or weight of the product could be different. *

 
 
Versiones 1 to 1 of 1
 LC001LC002LC004LC006LC008LC010LC015LC020LC025LC030LC040LC050LC060LC080LC100LC125LC150LC200LC250LC300LC400LC500
Request offerRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequest
Power (kW)0,370,751,52,2345,57,5111518,522303745557590110150185220
Power (CV)0,512345,57,5101520253040506075100125150200250300
Current (A)12468101520253040506080100125150200250300400500
Losses (W)384855607385105123140152161270310400430500565730960105012201480
IP20202020202020202020200000000000000000000000
PhasesThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
UseOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFDOutput for VFD
Ambient temperature50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC50ºC
Thermic classH (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)
Electric shock protectionClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse I
Test voltage4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV4 kV
Converter voltage380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V380V ÷ 420V
A150150150150150180180240240240240300300300300300300360420420420480
B120120135135135150155170170195195192212212222272287318340355380370
C190190190195195215220285285285285355355405405379379473550550550620
D100100100100100140140200200200200200200200200200200240280280280320
E464661616182879999124124105125125135160175174179194219208
ø777777777771111111111111111111111
Weight (Kg)2,93,34,24,758,59,51516212229364345687790120135160195