Three phase reversible Autotransformer IP00

Three phase reversible autotransformer dry type without galvanic isolation, designed for voltage change 400V / 230V. Protection degree IP-00 with varnish finished. Its main advantage is that can be used to increase as much as reduce voltage (reversible).

 
 
    
Power rating
3 ÷ 1.000 kVA
Input voltage
3 x 400 V + N
Output voltage
3 x 230 V
Connection group
YN0
Frequency50/60 Hz
Ambient temp.
40 ºC
Insulation class
F (155ºC) up to ATS0315
H (180ºC) from ATS0400
Protection degree
IP-00
CoolingNatural air
Safety classClass I
Test voltage
3 kV
MarkedCE
StandardIEC/UNE-EN 61558-1
IEC/UNE-EN 61558-2-13
IEC/UNE-EN 60076-11


 

Series ATS

756 KB

 
 
 

Electrical diagram

 

 

Dimensions

 

* TORYTRANS reserves the right to modify the information in any time
and without prior notice. Design, dimensions or weight of the product could be different. *

 
 
Versiones 1 to 1 of 1
 ATS003ATS004ATS006ATS008ATS010ATS012ATS016ATS020ATS025ATS031ATS040ATS050ATS063ATS080ATS100ATS125ATS160ATS200ATS250ATS315ATS400ATS500ATS630ATS800ATS1000
Request offerRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequestRequest
Power (VA)3000400060008000100001200016000200002500031500400005000063000800001000001250001600002000002500003150004000005000006300008000001000000
PRI (V)400400400400400400400400400400400400400400400400400400400400400400400400400
SEC (V)230230230230230230230230230230230230230230230230230230230230230230230230230
IP00000000000000000000000000000000000000000000000000
PhasesThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phaseThree-phase
UseReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversibleReversible
Frequency50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz50/60 Hz
Ambient temperature40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC40ºC
Thermic classF (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)F (155ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)H (180ºC)
Electric shock protectionClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse IClasse I
Test voltage3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV3 kV
A240240240300300300360360420420420480480655655655655655660660720720780840840
B155165190180190220205225225235255240270325345375275305310380440470490515555
C26526527032032532537538043543543550050059559559581081087590587587595510251035
D200200200200200200320320350350350400400400400400400400480480480480660660660
E859512095105135125145140150170155185220240270220250265335340370395420460
ø77711111111111111111111131313131313131313161616
Weight (Kg)111320242839465770799610713617821125824230640256966475593111261292
Type1111111111122222333344444
GroupYN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0YN0